High Cycle Fatigue Loading Testing
Performance Requirement:
There is no crack or breakage appeared on test sample after loading.
Loading procedure
Repeating 2,000,000 cycles with the lower limit loading of 20% nominal stress of specified rebar and stress amplitude 1000 kgf/cm². Then release loading to 2% nominal stress of specified rebar.