High Cycle Fatigue Loading Testing

Performance Requirement:

There is no crack or breakage appeared on test sample after loading.

Loading procedure

Repeating 2,000,000 cycles with the lower limit loading of 20% nominal stress of specified rebar and stress amplitude 1000 kgf/cm². Then release loading to 2% nominal stress of specified rebar.

High Cycle Fatigue Loading Testing loading diagram